- Academic Platform Journal of Engineering and Smart Systems
- Volume:10 Issue:2
- Investigation of the effect of demagnetization fault at Line Start AF-PMSM with FEM
Investigation of the effect of demagnetization fault at Line Start AF-PMSM with FEM
Authors : Mustafa EKER, Mustafa ÖZSOY
Pages : 94-100
Doi:10.21541/apjess.1007894
View : 11 | Download : 5
Publication Date : 2022-05-01
Article Type : Research Paper
Abstract :In motors containing magnets, irreversible demagnetization failure is one of the factors that negatively affect motor performance. In this study, the traditional Axial Flux Permanent Magnet Synchronous Motor insert ignore into journalissuearticles values(AF-PMSM); rotor structure was changed and the structure that gained the feature of starting from the line was used. Line Start AF-PMSM with 5.5 kW shaft power has 4 poles and each pole consists of 5 magnets. Demagnetization failure was obtained by the flux values of the magnets in any pole are drawn to zero and virtual demagnetization failure is created at certain rates insert ignore into journalissuearticles values(20%, 40% and 60%);. With FEM, the data of the healthy and faulty motor were obtained. The data are then presented comparatively. Obtained data showed that demagnetization fault in Line Start AF-PMSM negatively affects motor performance, and the results are given in detail in the article. The original aspect of the study is that the demagnetization fault in Line Start AF-PMSM was investigated for the first time with FEM.Keywords : Line Start, Axial Flux PMSM, Demagnetization fault, FEM