- European Journal of Engineering and Applied Sciences
- Volume:7 Issue:2
- A Water Absorption Chamber Design for Cable Capacitance Measurement Tests
A Water Absorption Chamber Design for Cable Capacitance Measurement Tests
Authors : Ercan Ulutay, Metin Yurtsever, Avşin Öztaş, Uğur Akyol, Reşat Mutlu
Pages : 150-158
Doi:10.55581/ejeas.1598086
View : 67 | Download : 103
Publication Date : 2024-12-31
Article Type : Research Paper
Abstract :XLPO cables used in ships should be tested for water absorption. Test standards require the cables be submerged in a water absorption chamber and kept at 75 0C for 14 days. Once every 7 days, the cables within the chamber are tested by applying high voltage, and their capacitance, dissipation factor, stability factor, and relative Permittivity are measured. In this study, a water absorption chamber used in the experiments is designed using fiberglass material and controlled with an ENDA ET 4420 temperature controller. It is experimentally shown that the water absorption chamber performs well.Keywords : Güç Kabloları, Su Emme Testi, Kablo Testleri, Termal Tasarım, Isıtıcı Tasarımı