- Reliability and Validity of Use of A Smartphone Application For The Measurement of Gissane and Bohle...
Reliability and Validity of Use of A Smartphone Application For The Measurement of Gissane and Bohler’s Angles in Calcaneal Fractures
Authors : Onur GÜRSAN, Ertuğrul ŞAHİN
Pages : 181-186
Doi:10.5798/dicletip.1313245
View : 24 | Download : 20
Publication Date : 2023-06-12
Article Type : Research Paper
Abstract :Objective: Calcaneus is the most often fractured bone of all the tarsal bones in the human skeleton. Initial evaluation of a suspected calcaneal fracture is often assessed with Böhler’s and Gissane’s angles. The aim of this study was to compare the reliability and consistency of measurements of Gissane and Böhler’s angles by using a smartphone application insert ignore into journalissuearticles values(iPinPoint); and a computer-based program Methods: A total of 41 patients were included. The measurement of fracture angulation was done by two orthopaedic surgeons twice one month apart using iPinPoint and Sectra. The inter- and intraobserver reliability was measured using intraclass correlation coefficients insert ignore into journalissuearticles values(ICCs);. The intraobserver variabilities between the SECTRA and iPinPoint measurements for each participant were evaluated. Interobserver variability was also determined by comparing the results of Böhler’s and Gissane angles among the surgeons Results: The mean difference between the two techniques were 0.9° and 0.4° for Gissane and Böhler’s angles, respectively. The intraobserver reliability of Gissane and Bohler’s angles between smartphone and computer for each observer was very good insert ignore into journalissuearticles values(ICC=0.938 vs. 0.943, ICC= 0.970 vs 0.979, respectively);. Interobserver reliability between two observers for SECTRA and iPinPoint results were very good insert ignore into journalissuearticles values(ICC=0.955, ICC=0.905 respectively);. Conclusion: iPinPoint application can be used for the measurement of Gissane and Bohler’s angles safely. In addition, there are very good results that support it as a reliable and reproducible tool for SECTRA measurements.Keywords : Calcaneus, fracture, measurement, smartphone, Interobserver reliability, Interobserver reliability